Product Qualifying Criteria (3th Batch)
Date of Release : 20 March 1995
Date of Review :
1 November 1998

Category
Qualifying Criteria (Part I )
1) Standard Laundry Powder Detergent (GLS-009-03) a) Biodegradability of the detergent must be at least 90%
b) pH value of the detergent must not exceed 11.
c) The detergent must no not contain any carcinogenic, allergenic or teratogenic substances or substances that are considered hazardous to the environment.
d) Certain substances in the detergents are to be excluded or limited to amount specific as attached.
2) Concentrated Laundry Powder Detergent
(GLS-010-03)

do

3) Laundry Liquid Detergent
(GLS-011-03)
do
4) Dishwashing Detergent
(GLS-012-03)
do
5) Floor Cleaner
(GLS-013-03)
do
6) Washing Machines
(GLS-014-03)
Updated 4th May '04

The washing machine must meet the following criteria for its full load, cold wash, normal cycle:

1.   15 liters of water per kg/wash

2.   0.22kWh for hot water cycle kg/wash *

3.   0.04kWh for cold water cycle kg/wash

4.   The airborne acoustical noise during the water extracting shall not exceed 60 dB(A) during washing and 76dB(A) during the spin cycle**

5.   Plastic Parts:

a.   Substances based on cadmium, lead, mercury or their compounds, or the following flame-retardant shall not be added to the plastic materials:

i. Polybrominated biphenlys (PBB); and

ii. Polybrominated diphenyl ethers (PBDE).

6.   Surface Treatment:

a.   Paints shall not contain pigments or additives based on cadmium, lead, chromium, mercury or their compounds. Metals shall not be coated with cadmium, chromium, nickel or their compounds. Please refer to Paints and Varnishes for additional requirements.

7.   Packaging requirements:

a.   Packaging materials shall not contain chlorine-based plastics

Detergents:

For items a), b), d) & washing machines Applicant needs to submit a sample for test at accredited SAC-SINGLAS (The Singapore Laboratory Accreditation Scheme) Laboratories. Application shall be accompanied by a test report.
For item c) Declaration by the Chief Executive Officer or equivalent of the manufacturer is required.

Washing Machines:

All tests must be conducted on Standard setting / mode
(i.e. non fuzzy logic , smart, quick wash or equivalent modes)
* Machines that have a hot water cycle with a built in heating system must comply with the energy usage requirements stated above of Hot Water cycles. Pleaser refer to American National Standards Institute (ANSI) IEC 60456 test standards for reference. The ambient water temperature in Singapore is between 27 - 30° C please test with a maximum heated temperature of 60° C.
** Pleaser refer to European EN 60704, EN 60456 or American National Standards Institute (ANSI) IEC 60704-2-4 Ed. 2.0 b:2001 test standards for reference.

 

Qualifying Criteria Detergents Only (Part II )
Concentrations of phosphate, chemical dye and optical brightener to be capped at the following limits :
Chemical Substances Laundry Standard Powder Detergent Laundry Concentrated Powder Detergent Laundry Liquid Detergent Dishwashing Detergent Floor Cleaner
Phosphate as of P2 O5 20% 20% 20% 5% 5%
Chemical Dye 0.05% 0.05% 0.05% X 0.05%
Optical Brightener 0.05% 0.05% 0.05% X -

 

Qualifying Criteria Detergents Only (Part III )
The following substances to be excluded from the detergent formulation :
Chemical Substances Laundry Standard Powder Detergent Laundry Concentrated Powder Detergent Laundry Liquid Detergent Dishwashing Detergent Floor Cleaner
Phosphonate X X X X X
APEO (Alkylphenol ethoxylate) X X X X X
EDTA (Ethylene diamine tetraacetic acid) X X X X X
NTA (Nitrilotriacetic acid) X X X X X
Perborate X X X - -
Chlorine Bleach X X X - -
Fabric Softner X X X - -
Halogenated Hydrocarbon X X X X X
Formalin - - X X X
           
X To be excluded from the detergent formulation.
- denotes "not applicable"

 

 

back